SEARCH

United States 03V190000

R-VISION

FUEL SYSTEM, GASOLINE — R-VISION/FUEL RETURN LINE · May 8, 2003

The problem

ON CERTAIN MOTOR HOMES, THE CHASSIS FUEL RETURN LINE, WHICH IS TAPPED TO SUPPLY FUEL TO THE GENERATOR, HAS BEEN FOUND TO HAVE PRESSURES THAT EXCEED THE MAXIMUM ALLOWED BY THE GENERATOR MANUFACTURER. AS A RESULT, IF THE GENERATOR IS OPERATED AT THE SAME TIME THE CHASSIS ENGINE IS RUNNING, EXCESS FUEL COULD BE DELIVERED TO THE GENERATOR, CREATING A POTENTIAL FOR A GENERATOR STALL AND POSSIBLE FUEL SPILL.

Risk

IN THE EVENT OF A FUEL SPILL, A FIRE COULD OCCUR.

What owners should do

DEALERS WILL INSTALL AN APPROVED KIT THAT DRAWS THE GENERATOR FUEL SUPPLY DIRECTLY FROM THE FUEL TANK. OWNER NOTIFICATION BEGAN MAY 5, 2003. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT R-VISION AT 1-574-268-2111.

Units 134

Official record All recalls